Glossary entry

English term or phrase:

landing valve

Serbian translation:

kosi ventil

Added to glossary by Goran Stankovic
Nov 20, 2013 10:23
10 yrs ago
11 viewers *
English term

landing valve

English to Serbian Tech/Engineering Engineering (general)
Buildings with fire-fighting stairs will be fitted with a wet standpipe system, adjacent to the stairs. Hose-reels and fire-hoses will be positioned within the same cabinet as the standpipe landing valve (fire main outlet).
Change log

Dec 4, 2013 04:23: Goran Stankovic Created KOG entry

Proposed translations

+5
1 hr
Selected

kosi ventil

Peer comment(s):

agree Goran Tasic
1 day 46 mins
Hvala
agree Aleksandar Skobic
12 days
Hvala
agree marink0
12 days
Hvala
agree Marija Matkovic
12 days
Hvala
agree Irena Ristic
12 days
Hvala
Something went wrong...
4 KudoZ points awarded for this answer. Comment: "Selected automatically based on peer agreement."
17 mins

ugaoni ventil

Peer comment(s):

neutral Mira Stepanovic : Ugaoni ventil = angle valve; tačno je da se radi o ventilu za hidrantsku mrežu ali ne mora obavezno da bude ugaoni, ugaoni ventil je samo jedan od tipova priključnih ventila. U svakom slučaju izvinite. :-)
29 mins
Nema problema :)
Something went wrong...
+2
21 hrs

priključni ventil

To je ventil koji sa jedne strane ima priključak za cev hidrantske mreže, sa druge ima priključak za crevo a nalazi se u hidrantskom ormariću. Hidrantski ormarići se nalaze na podestima/odmorištima požarnih stepeništa, otuda "landing valve".
http://www.linkedin.com/groups/What-is-Landing-valve-fire-14...
What is Landing valve or fire department valve?
---
Landing valve is the term used in the UK to refer to the 2 1/2" standpipe hose valves.
---
In Canada we called that Hose Connection.
---
Landing valve or fire department valve :
A Class I standpipe system shall provide 21/2-in. (63.5-mm) hose connections to supply water for use by fire departments and those trained in handling heavy fire streams.in the following locations:
(a) At each intermediate landing between floor levels in every required exit stairway.
Exception: Hose connections shall be permitted to be located at the main floor landings in exit stairways where approved by the authority having jurisdiction.
(b) On each side of the wall adjacent to the exit openings of horizontal exits.
(c) In each exit passageway at the entrance from the building areas into the passageway.
(d) In covered mall buildings, at the entrance to each exit passageway or exit corridor, and at exterior public entrances to the mall.
(e) At the highest landing of stairways with stairway access to a roof, and on the roof where stairways do not access the roof. An additional 21/2-in. (63.5-mm) hose connection shall be provided at the hydraulically most remote riser to facilitate testing of the system...

landing valve = fire department valve = hose connection

Ovo je oprema koja se nalazi u hidrantskom ormariću koji se spominje u tekstu:
http://www.tehnototal.co.rs/Hidranti i oprema.html
Ormar za zidni hidrant
Dimenzije: 500x500x144 mm
Sadržaj:
1 x crevo TREVIRA ø52 od 15m
1 x mlaznica ø52
1 x priključni ventil 2" - ugaoni ili drugi

Ovaj ventil može ali ne mora obavezno da bude ugaoni ventil, pogledajte koliko ima raznih tipova priključnih ventila (landing valve), ovde su navedeni samo neki tipovi:
http://www.naffco.com/products/pr11/pr11010100.html
Oblique Landing Valve
Right Angle Landing Valve
Straight Through Landing Valve (Horizontal Type)
Bib Nose Type Landing Valve
---
Landing Valves are used for fighting fire with water and accordingly mounted in fire hydrant system at Internal or External places. The landing valves are sometimes also referred to as internal hydrants because they are usually fitted inside the buildings for wet hydrant system.

Još tipova priključnih ventila:
http://wofu001.en.made-in-china.com/productimage/pBeJWPUuVfV...

http://www.search-document.com/pdf/3/din-14461-3.html
Vsebina omarice: 1 kom priključni ventil 2 '' DIN 14461-3
---
hose connection acc. to DIN 14461-3

Pogledajte sliku ovde:
http://katalog.fln-neuruppin.de/en/products/1428/
Landing valve 2" brass, DIN 14461-3
---
inlet male thread for pipe connection, outlet brass coupling size Storz "C" for hose connection.

Poslednja rečenica otprilike glasi: na ulazu unutrašnji navoj za priključak cevi*, na izlazu mesingana spojnica za priključak creva
*cev hidrantske mreže

http://www.latipro.net/PagAdm/PPHOrmar.asp
Zidni hidrantski ormarić HOZ (540 x 540 x 144 mm)
Crevo trevira Ø 52 L 15 m
Mlaznica sa ručkom Ø 52
Priključni ventil 2" - ugaoni

--------------------------------------------------
Note added at 21 hrs (2013-11-21 08:13:22 GMT)
--------------------------------------------------

http://www.techstreet.com/products/1266988
DIN 14461-3
Delivery valve installations for firefighting purposes - Part 3: Fire hose valves for nominal pressure PN 16
Peer comment(s):

agree Olivera R : Или ''хидрантски прикључак''. Овде недвосмислено. Још је у загради fire main outlet. (fire main - a pipe for water, to be used in putting out fire).
6 hrs
Hvala, ali ja bih se ovde ipak odlučila za priključni ventil. :-)
agree djurovic
8 days
Hvala!
Something went wrong...
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search